meta data for this page
  •  

Search

You can find the results of your search below.

Matching pagenames:

Fulltext results:

Connection system @integrated_drive_motors
17 Hits, Last modified:
| |2|CAN_H|CAN HIGH| | |3|GND|Ground| | |4|+24VDC|Power| | |5|+24VDC|Power| | |6|GND|Ground| | |7|GND|Ground| | |8|CAN_H|CAN HIGH| | |9|CAN_RES|TERMINATION RESI... |2|RS485_A|Modbus A| | |3|GND|Ground| | |4|+24VDC|Power| | |5|+24VDC|Power| | |6|GND|Ground| | |7|GND|Ground| | |8|DIG_IN0|Digital Input 0 (24V logic)|Enable /
Power Port Pinouts @nl7_servo
11 Hits, Last modified:
====== Power Port Pinouts ====== ===== Overview ===== {{:nl7_servo:port_3r.jpg?nolink&500x592|port_3r.j... ion port| |CN6|STO Safe Torque Off port| |X1|Main Power Supply| ===== X1 Port main power supply (230 VAC models) ===== |**Pin** |**Functions** |**Remarls** | ... t is recommended to connect a line filter to main power supply; \\ \\ It is recommended to install a fus
Protection
9 Hits, Last modified:
h voltage installations. \\ * Before switching on power the ground wire must be permanently connected to ... nt must be disconnected from the mains voltage or power supply. \\ * Make sure the equipment cannot be sw... s: \\ * Wait five (5) minutes after switching off power to allow capacitors to discharge before beginning... electrical connection points of a component while power is turned on. \\ * Install the covers and guards
Wiring Diagram @nl7_servo
7 Hits, Last modified:
le phase and three phase 220VAC. Only driver with power rating above 1500W supports three phase 220VAC. * Please use a circuit breaker for the main power supply to prevent damage to the product or machin... of the capacity when connect to a 24VDC switching power supply, especially if power supply is shared between multiple components. Insufficient supply current wi
Pacdrive 3 - Schneider Electric @reverso_encoder
7 Hits, Last modified:
** (a jumper on the temperature connectors on the power port must be arranged). The Motor Data must be s... TRUE. After the sucessfully procedure, swtich the power supply of the encoder and the drive off. When the... alue without errors. Now select the PSM_Lexium62 power supply window, provide the power lines (400V) to the drive and set PowerSupplyCheckSet to 1. Go back to
Faults Diagnosys and reset @integrated_drive_motors
6 Hits, Last modified:
the Flash memory|Try to reset the system using a power cycle and retry| |13|0xD|SINCOS_OVERRANGE|Encoder... - Paramenter 69 (dec)| |15|0xF|MOTOR_OVERCURRENT|Power stage overcurrent|–| |16|0x10|MOTOR_DCLINK_OVERRRANGE|DC Link over range|Check the power supply level or the current capabilty of your power supply. Check the threshold level in the Parameter 4
SIN/COS Encoder converter - Interpolator @miniature_motors
6 Hits, Last modified:
otors:nq6_2.jpg?nolink&700x405|nq6_2.jpg}} ===== Power supply ===== ==== Using programming cable ==== When the programming calbe is used the power supply for Interpolator and the connected SIN/COS... t for the correct ioperation) or with external 5V power supply connected\\ on the power X1. {{:miniature_motors:connection_2.jpg?direct&400x415|connection_2.jp
Electrical characteristics @motolab_actuator
6 Hits, Last modified:
100 A| |Rated current (max)|A|50 A| |Rated output power (max)|A|3.6 kW| |PWM Frequency|kHz|10| ===== Con... S402) * 1 RS232 with MODBUS RTU protocol ===== Power supply ===== \\ Phoenix Contact TRIO-PS-2G/3AC/24DC/40. 24 VDC output 40 Amp Power Supply 3-phase 320 -575 Vac input. {{:motolab_ac... link&200x200}} Omron S8JX-P Switch Mode DIN Rail Power Supply, 100 → 240V ac ac, dc Input, 12V dc dc Out
Cable configuration @green_drive_iso
5 Hits, Last modified:
ubular linear motors are provided with signal and power cable ready to be connected to different servo drives.\\ Two set of connectors are used M23 (power) and M17 (signal) speedtec and M15 (ytec) for sma... jpg?nolink&711x314|hall_signal_option.jpg}} ==== Power cable ==== {{:green_drive_motors:power_cable.jpg?nolink&311x146|power_cable.jpg}}
Cable configuration @green_drive_motors
5 Hits, Last modified:
ubular linear motors are provided with signal and power cable ready to be connected to different servo drive.\\ Two set of connectors are used M23 (power) and M17 (signal) speedtec and M15 (ytec) for sma... s_therm.jpg?nolink&489x330|biss_therm.jpg}} ==== Power cable (flying leads => DE20000771 for M23 connect... 5 connector on motor side) ==== {{:green_drive_motors:power_cable.jpg?nolink&311x146|power_cable.jpg}}
Electrical connection @ironcore_motors
5 Hits, Last modified:
e_exit.jpg?nolink&700x206|cable_exit.jpg}} ===== Power connection ===== L-series motors are normally provided with 1 m flexible shielded power cable without a connector (lead wires). Here is t... in respect to the motor and winding code. ===== Power cable with connector ===== By request, L-series ... motors can be provided with 1 m flexible shielded power cable and a male Intercontec Speedtec series conn
Installation @mbd_servo_drive
5 Hits, Last modified:
(by removing the fuses or disconnecting the main power switch). For this operation place the converter o... he original installation place.\\ All control and power may be live, even though the motor is not rotatin... emote control switch or remote-control switch all power supply phases of the product.\\ In the case of 3-phase power supply interrupt L1, L2 and L3; in the case of si
Starter Status Area @nilab_starter
5 Hits, Last modified:
w we have all the motor controls: \\ - ON - Motor power on \\ - OFF - Motor power off \\ - FAULT RESET - Reset the active fault \\ - RESET AUTOMATIC HOMING - Re... \ * 4132 - Motor Encoder Arctan [Lsb] \\ * 4631 - Power Dcbus Voltage [V] \\ * 4630 - Power i2t Value \\ * 4129 - Power i2t 1sec \\ * 7 - Motor Drive Temperatur
Input / Output Circuits @nl7_servo
5 Hits, Last modified:
s: DO1 and DO2 are single-ended, sharing a common power supply ground terminal; DO3+/DO3- is double-ended, having an isolated 24v power supply. {{:nl7_servo:io_2.jpg?nolink&655x716|io_2.jpg}} * Power supply is provided by user. Please be aware that reversed power supply polarity might cause damage to the driver.
Safe Torque Off (STO) Port - CN6 @nl7_servo
5 Hits, Last modified:
supply by blocking of PWM control signal from the power module. When the motor current is cut off, the mo... dually by blocking of PWM control signal from the power module through 2 isolated circuits. When a STO er... n be chosen. * STO is not meant to cut off the power supply of the servo drivers and motors completely. Please power off and wait for a few minutes before starting ma
Glossary
4 Hits, Last modified:
Connectors and indicators @nli_eth
4 Hits, Last modified:
Connectors and indicators @gdi_ethercat
3 Hits, Last modified:
Siemens Sinamics S120 / G120 @green_drive_iso
3 Hits, Last modified:
Siemens Sinamics S120 / G120 @green_drive_motors
3 Hits, Last modified:
Demo Case @integrated_drive_motors
3 Hits, Last modified:
Safety @integrated_drive_motors
3 Hits, Last modified:
Motor cooling @ironcore_motors
3 Hits, Last modified:
Fault and Warning Messages @mbd_servo_drive
3 Hits, Last modified:
Technical characteristics @mbd_servo_drive
3 Hits, Last modified:
Technical Parameter @nl_eb15_safety
3 Hits, Last modified:
Application range
2 Hits, Last modified:
Force vs. speed curve
2 Hits, Last modified:
Connection system @gdm_linear_axes
2 Hits, Last modified:
Maintenance @green_drive_iso
2 Hits, Last modified:
Maintenance @green_drive_motors
2 Hits, Last modified:
Pacdrive3 - Lxm62 servo drive @green_drive_motors
2 Hits, Last modified:
Green Drive in Parallel drive @green_drive_motors
2 Hits, Last modified:
Maintenance @integrated_drive_motors
2 Hits, Last modified:
Nidec M700 Servo Drive @lma_actuator
2 Hits, Last modified:
Digital Signals @mbd_servo_drive
2 Hits, Last modified:
How to calculate the motor phase angle @mbd_servo_drive
2 Hits, Last modified:
Safety @mbd_servo_drive
2 Hits, Last modified:
MBD 230/400 Servo Drive @mbd_servo_drive
2 Hits, Last modified:
Connectors @motolab_actuator
2 Hits, Last modified:
How to save and reload the configuration @nilab_starter
2 Hits, Last modified:
Regenerative resistor @nl7_servo
2 Hits, Last modified:
I/O Signal Port - CN1 @nl7_servo
2 Hits, Last modified:
NL7 Servo Drive @nl7_servo
2 Hits, Last modified:
Manufacturer responsibility
1 Hits, Last modified:
Main technical data @epulse50_dc_servodrive
1 Hits, Last modified:
Encoder type @gdm_linear_axes
1 Hits, Last modified:
How to use connectors @green_drive_iso
1 Hits, Last modified:
Servo Drive Compatilibity @green_drive_iso
1 Hits, Last modified:
Cable coding system @green_drive_motors
1 Hits, Last modified:
CB Test Certificate @green_drive_motors
1 Hits, Last modified:
How to use connectors @green_drive_motors
1 Hits, Last modified:
Servo Drive Compatilibity @green_drive_motors
1 Hits, Last modified:
EtherCAT to MODBUS RTU Gateway @gtw_ethercat
1 Hits, Last modified:
MODBUS RTU debug mode @integrated_drive_motors
1 Hits, Last modified:
MODBUS RTU Interface @integrated_drive_motors
1 Hits, Last modified:
MODBUS RTU Communication @integrated_drive_motors
1 Hits, Last modified:
NLi integrated linear motors @integrated_drive_motors
1 Hits, Last modified:
Connectors @integrated_rotolinear
1 Hits, Last modified:
Motor components arrangement @ironcore_motors
1 Hits, Last modified:
L/LK Ironcore linear motors @ironcore_motors
1 Hits, Last modified:
LM Linear Stage @lm_linear_axes
1 Hits, Last modified:
Connectors Pinout @lma_actuator
1 Hits, Last modified:
Drive with analog reference @mbd_servo_drive
1 Hits, Last modified:
External braking resistor @mbd_servo_drive
1 Hits, Last modified:
Safe Torque Off Inputs @mbd_servo_drive
1 Hits, Last modified:
Cable coding system @mbm_motors
1 Hits, Last modified:
MBM Connectors on motor side @mbm_motors
1 Hits, Last modified:
MBM AC Brushless Servomotors @mbm_motors
1 Hits, Last modified:
GHA Coating @miniature_motors
1 Hits, Last modified:
NL miniature linear motors @miniature_motors
1 Hits, Last modified:
Cables accessories @motolab_actuator
1 Hits, Last modified:
MEQI Ballscrew actuator @motolab_actuator
1 Hits, Last modified:
Starter interface windows @nilab_starter
1 Hits, Last modified:
Encoder @nl_bcj_linear_stage
1 Hits, Last modified:
NL-EB15 Compact safety light curtain @nl_eb15_safety
1 Hits, Last modified:
Holding brake @nl7_servo
1 Hits, Last modified:
NLi-EtherCAT integrated linear motors @nli_eth
1 Hits, Last modified:
Connector pinout @reverso_encoder
1 Hits, Last modified:
Technical Data @reverso_encoder
1 Hits, Last modified:
ULCO 44/66/88/132 - Belt driven linear units @ulco
1 Hits, Last modified:
ULCO 44 @ulco
1 Hits, Last modified:
DokuWiki @wiki
1 Hits, Last modified: