Safety

Soft landing function

For vertical application, it is possible to activate a function call soft landing. This function executes automatically at every switch-off (Disable command via sofwtare or via digital input) an homing procedure.
This to avoid that the motor falls down every time is switched off. Function can be activate using NiLAB Starter Software in Motor parameter windows.

soft.jpg

Safety Relais - External STO Function

In order to emulate the STO function, an external safety relais can be used to switch-on and off the 24VDC power to the integrated linear motor.

safety_relais.jpg

For example using Wieland SNA 4043K (https://eshop.wieland-electric.com/products/en/device-for-monitoring-of-safetyrelated-circuits-sna4043ka-acdc-24v-a/r1.188.1810.0?locale=en)

The connection will be the following:

safety_conn.jpg

PLC Enable must be set high (Pin S12) and subsequently the PLC Reset signal (Pin 34) must be applied to power on the relais. In case of emergency event, PLC Enable must be set low to switch off the relais cutting off the 24VDC power .