Fulltext results:
- RS232 interface, PC connection (C2) @mbd_servo_drive
- ====== RS232 interface, PC connection (C2) ====== The setting of all parameters can be made by the commission... olink&800x305|rs232_pin.jpg}} ===== Serial cable connection ===== {{:mbd_servo_drive:rs232_schema.jpg?nolink&800x396|rs232_schema.jpg}} ===== Connection using TKSED Software ===== <font 10pt/Verdana,sa... s-serif;;inherit;;inherit>correctly configure the connection</font> \\ <font 10pt/Verdana,sans-serif;;inherit
- SIN/COS Encoder converter - Interpolator @miniature_motors
- ns including amplifier settling\\ - Direct sensor connection; selectable input gain\\ - Input frequency of up ... connected\\ on the power X1. {{:miniature_motors:connection_2.jpg?direct&400x415|connection_2.jpg}} ==== Using Servo Drive ==== Connecting a servo drive BiSS interface... supply connected on port X1. {{:miniature_motors:connection_1.jpg?direct&400x406|connection_1.jpg}}{{:miniatu
- Protection
- onnected to all electrical units according to the connection diagram. \\ * Do not operate electrical equipment... is safe to touch. \\ * Never touch the electrical connection points of a component while power is turned on. \... d points before power is switched on. Look at the connection diagram. This is even necessary for brief tests. ... over its entire course for this safety conductor connection! \\ * Prior to startups, even for brief tests, al
- MODBUS RTU Interface @integrated_drive_motors
- i/Modbus]] {{:integrated_drive_motors:modbus_rtu_connection.jpg?nolink&650x211|modbus_rtu_connection.jpg}} As in the schema above, for long connection we suggested to use a terminal resistor of 120 ohm. If th... cable. {{:integrated_drive_motors:terminal_block_connection.jpg?nolink&582x385|terminal_block_connection.jpg}
- Power Port Pinouts @nl7_servo
- or U phase terminal| \\ Please ensure proper wire connection on motor.| |V|Motor V phase terminal| \\ Please ensure proper wire connection on motor.| |W|Motor W phase terminal| \\ Please ensure proper wire connection on motor.| |PE|Motor potective Earth|Please groun... or V phase terminal| \\ Please ensure proper wire connection on motor.| |W|Motor W phase terminal| \\ Please e
- CANopen interface @mbd_servo_drive
- The D-SUB C6/C7 connectors are used for CANopen connection. The default baud rate is 500Kbps, the maximum ac... _2.jpg}} ===== Connections example ===== \\ The connection CANOpen must be made with a pair of shielded cabl... drive:can_3.jpg?nolink&650x408|can_3.jpg}} ===== Connection example with 3 devices ===== Here's an example o... f the conductor by means of a secure and spacious connection. {{:mbd_servo_drive:can_4.jpg?nolink&800x378|can
- Connection to 3-phases Mains Supply Networks @mbd_servo_drive
- ====== Connection to 3-phases Mains Supply Networks ====== ===== Connection with 3x400 VAC power lines ===== The connection of the main electrical supply is made via the C4 connector. ... ive:main_2.jpg?nolink&800x761|main_2.jpg}} ===== Connection with 230VAC single phase powerline ===== Please
- Analog control @integrated_drive_motors
- be equipped with an additional M12 connector. See connection system pinout:[[:integrated_drive_motors:connection_system|https://www.nilab.at/dokuwiki/doku.php?id=integrated_drive_motors:connection_system|]] ===== Analog current (4 to 20 mA) ====
- Electrical connection @ironcore_motors
- ====== Electrical connection ====== ===== Cables ===== The electrical connection of linear motors is performed with using of free cable ... .jpg?nolink&700x206|cable_exit.jpg}} ===== Power connection ===== L-series motors are normally provided with
- Liquid Cooled Motors (LK) @ironcore_motors
- ion_symbol.jpg}}|**Risk of damage!** \\ Note that connection to the cooling circuit must be provided with use ... Careless handling can easily cause damage of the connection fitting. \\ **When connecting the linear motor to... support the linear motor inlet and outlet fitting connection (see Figure below). Failure to do so may result i
- Installation @mbd_servo_drive
- that you must provide an electrically conductive connection as robust as possible (large surface area) betwee... bar or metal plate mounting in the cabinet. This connection is designed to allow the dispersion of high frequ... wn in the diagrams of this manual as a protection connection (according to European Standard EN60204). {{:mbd
- Safe Torque Off Inputs @mbd_servo_drive
- orque Off Inputs ====== ===== 24V / STO A-B (C1) Connection ===== The C1 connector includes the power supply... he servo amplifier is disabled| ===== Example of connection using STO-A and STO-B inputs ===== {{:mbd_servo_... .jpg?nolink&600x511|sto_1.jpg}} ===== Example of connection to avoid the use of STO-A and STO-B inputs =====
- Inputs and outputs connection @epulse50_dc_servodrive
- ====== Inputs and outputs connection ====== In Epulse50 are available 2 programmable digital inputs, 2 analog... der to use the CanOPEN termination, please make a connection (jumper) between pin 1 and pin 9__. {{:epulse50_
- Connectors and indicators @gdi_ethercat
- Active|Red| |EL1|EtherCAT communication|Active - Connection to Ethercat|Orange| |EL2|EtherCAT communication|B... ivity|Green| |EL3|EtherCAT communication|Active - Connection to Ethercat|Orange| |EL4|EtherCAT communication|B
- How to use connectors @green_drive_iso
- How to use speedtec connector ===== The standard connection system based on speedtec connector on the cable m... LDER AND THE ENCODER FEEDBACK WILL STOP TO HAVE A CONNECTION TO THE DRIVE !!!!** {{:green_drive_motors:signal